Application Scope:
Be used for the drainage of serious polluted water in factory or commerce. Be used for the drainage of sewage in residential area. Be used for the drainage of sewage in hospital and hotel. Be used for the water supply and drainage in waterworks. Be used for the water supply and drainage system in city sewage treatment factory. Be used for the drainage of water in civil air defense system. Be used for the municipal engineering and construction site. Be used for agricultural methane, agricultural irrigation.
Application Conditions:
PH: 5- 9, the temperature of water is less than 60º C. The content of impurity is less than 25%.
Installation Methods:
The pump can be installed in fixed and free stand style.
Fixed Wet Installation
The unique auto-coupling system owned by our corporation is used. The pump slips down to the duck-foot pedestal along the guide rail and positioned automatically, tightly and reliably.
Free stand Installation
Pump stand on the bottom by support plate and connected with the flexible pipe. This kind of installation is used in emergency, maintenance and construction (limit to the pump with power less than 4 kW. )
AS, AV SERIES SUBMERSIBLE SEWAGE PUMP
AS (AV) 16 - 2W/CB
AS --- Non-clog, single channel semi-open impeller sub-sewage pump
AV --- Vortex impeller sub-sewage pump
16 --- Power P2*10 kW
2 --- Motor pole
W --- Meaning single phase, without it meaning three phase
CB --- Contra block device
AS/AV SERIES SUBMERSIBLE SEWAGE PUMP
AS,AV10-2CB
AS/AV--- AS single impeller
        AV vortex impeller
10 --- power: 1kw
Technical Characteristic
Installation Size (look table)

If need any type, please contact us.
We aslo could redesign it for customer's requirement
No. | Model | Capacity M3/h |
Head m |
Power kw |
Speed r/min |
Outlet mm |
Dia. Of Solid passed mm |
Weight kg |
1 | AS10-2CB | 15 | 4.5 | 1 | 2850 | 80 | 30 | 30 |
2 | AS16-2CB | 29 | 7.6 | 1.6 | 2850 | 80 | 30 | 33 |
3 | AS30-2CB | 42 | 11 | 2.9 | 2850 | 80 | 30 | 40 |
4 | AS55-2CB | 65 | 12 | 5.5 | 2850 | 100 | 50 | 165 |
5 | AS55-4CB | 100 | 7.5 | 5.5 | 1450 | 150 | 80 | 180 |
6 | AS75-2CB | 85 | 13 | 7.5 | 2850 | 100 | 50 | 185 |
7 | AS75-4CB | 145 | 10 | 7.5 | 1450 | 150 | 80 | 200 |
8 | AV14-4 | 22 | 5.8 | 1.4 | 1450 | 80 | 30 | 33 |
9 | AV55-2 | 30 | 20 | 5.5 | 2850 | 100 | 50 | 150 |
10 | AV75-2 | 30 | 25 | 7.5 | 2850 | 100 | 50 | 150 |
11 | AS10-2W/CB | 15 | 4 | 0.8 | 2850 | 80 | 30 | 30 |
12 | AS16-2W/CB | 22 | 6 | 1.2 | 2850 | 80 | 30 | 33 |
Application Scope:
Be used for the drainage of serious polluted water in factory or commerce. Be used for the drainage of sewage in residential area. Be used for the drainage of sewage in hospital and hotel. Be used for the water supply and drainage in waterworks. Be used for the water supply and drainage system in city sewage treatment factory. Be used for the drainage of water in civil air defense system. Be used for the municipal engineering and construction site. Be used for agricultural methane, agricultural irrigation.
Application Conditions:
PH: 5- 9, the temperature of water is less than 60º C. The content of impurity is less than 25%.
Installation Methods:
The pump can be installed in fixed and free stand style.
Fixed Wet Installation
The unique auto-coupling system owned by our corporation is used. The pump slips down to the duck-foot pedestal along the guide rail and positioned automatically, tightly and reliably.
Free stand Installation
Pump stand on the bottom by support plate and connected with the flexible pipe. This kind of installation is used in emergency, maintenance and construction (limit to the pump with power less than 4 kW. )
AS, AV SERIES SUBMERSIBLE SEWAGE PUMP
AS (AV) 16 - 2W/CB
AS --- Non-clog, single channel semi-open impeller sub-sewage pump
AV --- Vortex impeller sub-sewage pump
16 --- Power P2*10 kW
2 --- Motor pole
W --- Meaning single phase, without it meaning three phase
CB --- Contra block device
AS/AV SERIES SUBMERSIBLE SEWAGE PUMP
AS,AV10-2CB
AS/AV--- AS single impeller
        AV vortex impeller
10 --- power: 1kw
Technical Characteristic
Installation Size (look table)

If need any type, please contact us.
We aslo could redesign it for customer's requirement
No. | Model | Capacity M3/h |
Head m |
Power kw |
Speed r/min |
Outlet mm |
Dia. Of Solid passed mm |
Weight kg |
1 | AS10-2CB | 15 | 4.5 | 1 | 2850 | 80 | 30 | 30 |
2 | AS16-2CB | 29 | 7.6 | 1.6 | 2850 | 80 | 30 | 33 |
3 | AS30-2CB | 42 | 11 | 2.9 | 2850 | 80 | 30 | 40 |
4 | AS55-2CB | 65 | 12 | 5.5 | 2850 | 100 | 50 | 165 |
5 | AS55-4CB | 100 | 7.5 | 5.5 | 1450 | 150 | 80 | 180 |
6 | AS75-2CB | 85 | 13 | 7.5 | 2850 | 100 | 50 | 185 |
7 | AS75-4CB | 145 | 10 | 7.5 | 1450 | 150 | 80 | 200 |
8 | AV14-4 | 22 | 5.8 | 1.4 | 1450 | 80 | 30 | 33 |
9 | AV55-2 | 30 | 20 | 5.5 | 2850 | 100 | 50 | 150 |
10 | AV75-2 | 30 | 25 | 7.5 | 2850 | 100 | 50 | 150 |
11 | AS10-2W/CB | 15 | 4 | 0.8 | 2850 | 80 | 30 | 30 |
12 | AS16-2W/CB | 22 | 6 | 1.2 | 2850 | 80 | 30 | 33 |
AAC Steam Autoclave is also called still kettle,a large,heavy pressure container which is widely used in autoclaved aerated concrete block, concrete pipe pile, lime-sand brick, fly ash brick, microporous calcium silicate board, insulation asbestos board, high-strength gypsum building materials.
Generally after the process of steam curing (in fact it is Cao-Si02- H2O water thermal chemical reactions that take place inside the autoclave) products get the ultimate strength,it is the desired effect of increased service life.It also suitable for rubber and wood drying and anti-corrosion,etc.
Industrial Autoclaves,autoclave for aac plant,AAC Block Autoclave,autoclavable aerated concrete block,autoclave aerated concrete
Henan Yuanda Boiler Co., Ltd. , https://www.industrysboiler.com