Model NO.: SHSL-D2-604-14X630F2
Certification: RoHS, ISO
Condition: New
Product Name: Hotsale Intelligent Process Dry Air Cooler System
Air Volume: 63200 Cubic Meter
Feature: Circulating Water Pump
Net Weight: 1312kg
Fan Spec: 4*630
Fan Motor AMP: 20.0 a
Fan Motor Power: 11200W
Inlet Od: Dn125
Outlet Od: Dn125
Trademark: Shenglin
Transport Package: Wooden Packing
Specification: ISO9001: 2000
Origin: Shanghai, China
HS Code: 8415909000
Model NO.: SHSL-D2-604-14X630F2
Certification: RoHS, ISO
Condition: New
Product Name: Hotsale Intelligent Process Dry Air Cooler System
Air Volume: 63200 Cubic Meter
Feature: Circulating Water Pump
Net Weight: 1312kg
Fan Spec: 4*630
Fan Motor AMP: 20.0 a
Fan Motor Power: 11200W
Inlet Od: Dn125
Outlet Od: Dn125
Trademark: Shenglin
Transport Package: Wooden Packing
Specification: ISO9001: 2000
Origin: Shanghai, China
HS Code: 8415909000
      Hotsale Intelligent Process dry air cooler systemDescription of Technology:
The closed-loop, dry cooling technology operates by pumping water returning from
the process into heat exchangers and cooling it with ambient air flow. This process
provides clean water at the right temperature to process machines year round.
Desired water temperatures are continuously met through control and software that
provides fully-automatic water and energy savings adjustments based on actual
thermal load and outdoor temperatures.
To maintain water below setpoint in hot weather, defined as 29.4°C (85°F), outside
air passes through an adiabatic chamber before reaching the air-to-water heat
exchanger coils. Adiabatic mode keeps LWT below 35°C (95°F) even when ambient
temperatures reach 48.9°F (120°F). In the chamber, a fine mist of water (from a
separate source) is pulsed into the air stream, evaporates immediately and cools the
air before it impinges on the cooling coils. The spray function and volume of water
used is controlled by the microprocessor based on ambient temperatures. Only cool,
dry air makes contact with the heat exchanger coils, creating the concept of "dry
cooling". This ensures coils are kept completely dry and free of scale.
Technical data
Models | SBF634F10 | SBF634H10 | SBF636F10 | SBF636H10 |
SC4 cooling cap(KW) | 48.6 | 57.2 | 65.2 | 79.2 |
SC5 cooling cap(KW) | 41.6 | 50.2 | 53.6 | 64.2 |
Surface     | 210 | 292 | 312 | 436 |
Air flow    m³/h | 63200 | 59000 | 94800 | 88500 |
Air throw   m | 35 | 32 | 40 | 38 |
Net weight   kg | 660 | 740 | 960 | 1080 |
Fan spec. | 4*630 | 4*630 | 6*630 | 6*630 |
Fan mot.ampere  A | 20.0 | 20.0 | 30.0 | 30.0 |
Fan mot. Power  W | 11200 | 11200 | 16800 | 16800 |
Electric defrost   A | 56.6 | 56.6 | 85.5 | 85.5 |
Electric defrost   W | 32250 | 32250 | 48750 | 48750 |
W-defrost flow rate  m³/h | 14.0 | 17.3 | 17.3 | 21.6 |
Inlet OD      inch | 1-3/8*2 | 1-3/8*2 | 1-3/8*2 | 1-3/8*2 |
Outlet OD     inch | 2-1/8*2 | 2-1/8*2 | 2-1/8*2 | 2-1/8*2 |
*Two-system design for standard blast freezer models.






       Hotsale Intelligent Process dry air cooler system
Description of Technology:
The closed-loop, dry cooling technology operates by pumping water returning from
the process into heat exchangers and cooling it with ambient air flow. This process
provides clean water at the right temperature to process machines year round.
Desired water temperatures are continuously met through control and software that
provides fully-automatic water and energy savings adjustments based on actual
thermal load and outdoor temperatures.
To maintain water below setpoint in hot weather, defined as 29.4°C (85°F), outside
air passes through an adiabatic chamber before reaching the air-to-water heat
exchanger coils. Adiabatic mode keeps LWT below 35°C (95°F) even when ambient
temperatures reach 48.9°F (120°F). In the chamber, a fine mist of water (from a
separate source) is pulsed into the air stream, evaporates immediately and cools the
air before it impinges on the cooling coils. The spray function and volume of water
used is controlled by the microprocessor based on ambient temperatures. Only cool,
dry air makes contact with the heat exchanger coils, creating the concept of "dry
cooling". This ensures coils are kept completely dry and free of scale.
Technical data
Models | SBF634F10 | SBF634H10 | SBF636F10 | SBF636H10 |
SC4 cooling cap(KW) | 48.6 | 57.2 | 65.2 | 79.2 |
SC5 cooling cap(KW) | 41.6 | 50.2 | 53.6 | 64.2 |
Surface     | 210 | 292 | 312 | 436 |
Air flow    m³/h | 63200 | 59000 | 94800 | 88500 |
Air throw   m | 35 | 32 | 40 | 38 |
Net weight   kg | 660 | 740 | 960 | 1080 |
Fan spec. | 4*630 | 4*630 | 6*630 | 6*630 |
Fan mot.ampere  A | 20.0 | 20.0 | 30.0 | 30.0 |
Fan mot. Power  W | 11200 | 11200 | 16800 | 16800 |
Electric defrost   A | 56.6 | 56.6 | 85.5 | 85.5 |
Electric defrost   W | 32250 | 32250 | 48750 | 48750 |
W-defrost flow rate  m³/h | 14.0 | 17.3 | 17.3 | 21.6 |
Inlet OD      inch | 1-3/8*2 | 1-3/8*2 | 1-3/8*2 | 1-3/8*2 |
Outlet OD     inch | 2-1/8*2 | 2-1/8*2 | 2-1/8*2 | 2-1/8*2 |
*Two-system design for standard blast freezer models.






Â